Products

Products

shape shape shape

Variable Area Flowmeter

Category :  FLOW
Sub Category :  Flowmeter
Share:

SPECIFICATION

 

VARIABLE AREA FLOWMETER

General information

 
Product type Flowmeter
Product positioning For liquids and gases
Measurement principle Variable area float
Measured media Liquids, Gases

Operating conditions

 
Process pressure max. 1000 barg/
14500 psig
Process temperature -196…+400°C/
-320…+752°F

Materials

 
Measuring tube Austenitic stainless steel (1.4404/316L), Austenitic stainless steel (1.4435/316L), Austenitic alloy (2.4610/Alloy C4), Nickel alloy (2.4360/Alloy 400), Titanium alloy (3.7035/Ti-Grade 2), Austenitic stainless steel (1.4571/316Ti), Nickel-chrome-molybdenum-tungsten alloy (2.4819/Alloy C276), Nickel-chromium-molybdenum-niobium alloy (2.4856/Alloy 625), Austenitic stainless steel (1.4547/6Mo)
Gaskets None
Process connection Austenitic stainless steel (1.4404/316L), Austenitic stainless steel (1.4571/316Ti), Nickel alloy (2.4360/Alloy 400), Austenitic alloy (2.4610/Alloy C4), Nickel-chrome-molybdenum-tungsten alloy (2.4819/Alloy C276), Nickel-chromium-molybdenum-niobium alloy (2.4856/Alloy 625), Titanium alloy (3.7035/Ti-Grade 2), Austenitic stainless steel (1.4547/6Mo)

Process connections

 
Flange connections EN (1092-1): DN15…150
ASME (B 16.5): ½…6"
JIS (B 2220): 15…100A
Thread connections Female:
G½, G¾, G1¼, G1, G1½, G1¾, G2
½ NPT, ¾ NPT, 1 NPT, 2 NPT
Hygienic connections Clamp (DIN 32676): DN15, DN25, DN32, DN40, DN50, DN80
Clamp (ISO 2852): 25, 40, 51, 76.1
Tri-Clamp: ½", 1", 2"; Threaded ferrule (DIN 11851): DN15, DN25, DN40, DN50, DN80
Threaded ferrule (DIN 11864-1A,series C): 1", 2"
Flange with groove (DIN 11864-2): DN15, DN25, DN50, DN80
Threaded ferrule (SMS 1146): 25 mm, 51 mm, 76 mm

Approvals/Standards

 
Certificates/Approvals Others CRN, NACE
Certificates/Approvals Ex ATEX, IECEx, NEPSI, EAC Ex, cFMus, INMETRO, KCs, PESO, JPNEx
Certificates/Approvals Hygienic FDA, EC 1935/2004, GB 4806
Certificates/Approvals Marine RINA
Certificates/Approvals Nuclear Nuclear qualification on request (e.g. acc. to ASME III, RCC-M/E, etc.)
Certificates/Approvals Safety SIL 2

Communication

 
Analogue outputs 4…20 mA
Discrete outputs Limit switches, Pulse
Digital outputs FOUNDATION™ Fieldbus, HART®, Profibus-PA